Ceiling cooling and heating: performance, dew point and optimization for energy efficient buildings

Efficient ceiling heating and cooling with high energy efficiency
Ceiling heating and cooling systems are finding ever wider application in modern construction. While the energy consumption of buildings in terms of heating has been decreasing for a long time, interior cooling requirements are steadily increasing - and this is mainly due to increased heat gains through glazed surfaces a warming climatic conditions. Performance and the correct design of the ceiling cooling system thus play a key role.
Ceiling cooling and dew point work
Ceiling cooling operates with a cooling water operating temperature of dew point, which is calculated to be approximately 16 °C. This value forms the main limiting factor for sizing the cooling capacity.
Cooling and heating mats UNIVENTA DELGADO offer, thanks to their innovative design high heat transfer efficiency. They are compatible with standard plasterboards as well as boards with higher thermal conductivity, such as Rigips Climafit, which significantly increases ceiling cooling performance.
Climatic fluctuations and cooling reliability
Extreme summer temperatures and increased air humidity in recent years have brought frequent condensation problems. UNIVENTA DELGADO However, thanks to its high performance, it maintains its efficiency even at higher operating temperatures close to the dew point, thus allowing uninterrupted and safe cooling without the risk of condensation.
Maximum performance even with limited ceiling area
Radiant heating and cooling uses a large part of the ceiling area for energy distribution. However, elements such as lighting, loudspeakers, sensors or shading technology often interfere with this zone.
UNIVENTA DELGADO systems, designed for installation in plasterboard or plaster, allow flexible omission of certain areas, without significant loss of performance.
Energy savings through low-temperature operation
Thanks high heating and cooling performance heating and cooling water temperature can be optimised - lower heating temperature a higher cooling temperature increase efficiency heat pumps and reduce total energy consumption. This approach contributes significantly to sustainability of building operations.
Outdoor shading as a complement to passive cooling
Outdoor shading technology plays an important role in regulation of heat gains in summer. Much of the heat penetrates into the interior through the glazed surfaces, while high-quality shading effectively reduces overheating.
But it also leads to interior blackout, which is contrary to the requirements for bright, open and airy spaces. This is where the powerful ceiling cooling systems, such as UNIVENTA DELGADO, that reduce dependence on active shielding and allow comfortable climate even without permanent shading.
Summary of system benefits UNIVENTA DELGADO:
- High performance ceiling cooling and heating
- Compatibility with standard and conductive SDK boards
- Dew point optimization - safe operation without condensation
- Promoting the efficiency of heat pumps
- Can be combined with external shading without loss of comfort
- Flexible installation without the need for 100% ceiling coverage